In the evolving landscape of industrial automation, the need for reliable serial communication has never been greater. The Allen-Bradley 1734-485ASC serial interface module addresses this demand as part of the POINT I/O 1734 series. Designed to connect RS-422 or RS-485 networks, this module ensures stable data transmission in harsh environments. It uses shielded cables to minimize electrical noise, a common challenge in factory floors. With a voltage range of 10-28.8 volts DC and a nominal supply of 24 volts DC, it integrates seamlessly into existing systems. The 1734-485ASC is a key component for modernizing legacy serial devices.
The 1734-485ASC operates on a supply voltage of 24 volts DC nominal, drawing only 15mA at that voltage. It supports a voltage range of 10-28.8 volts DC, providing flexibility for various power sources. The module uses a key switch position of 2 for proper installation in the POINT I/O base. It is a serial interface module, not an analog or digital I/O module, focusing solely on ASCII communication over RS-422 or RS-485 networks. These specs ensure low power consumption and reliable serial connectivity.
Manufacturing facilities often rely on RS-422 or RS-485 networks to connect barcode scanners, printers, and weigh scales. The 1734-485ASC bridges these ASCII devices to a DeviceNet master, enabling real-time data exchange. In a packaging line, for example, it transmits product codes from scanners to the control system, reducing downtime. Similarly, in material handling, it links serial sensors to a PLC, improving inventory tracking. Its shielded cable requirement ensures signal integrity in electrically noisy environments, a critical factor for consistent operation.
Mount the 1734-485ASC on a DIN rail within a POINT I/O system. Use shielded cables for RS-422 or RS-485 connections, grounding only one side of the shield to avoid ground loops. The module does not support a chassis ground on its removable terminal block; instead, ground the shield at the DIN rail. Connect the terminal block using the 1734-TB, following markings on the module case. Set buffer sizes to 20 bytes for transmit and receive, adjusting via configuration if needed. Ensure the key switch is at position 2 before powering up.
Regularly inspect cable connections for wear or corrosion, especially in high-vibration areas. The module's low current draw of 15mA reduces heat buildup, extending its lifespan. Verify that shielded cables remain intact to prevent noise interference. Periodic checks of the DIN rail ground connection ensure consistent performance. For long-term reliability, maintain ambient conditions within the POINT I/O system's specified range. These practices minimize unexpected downtime and sustain data integrity.
Before purchasing the 1734-485ASC, confirm your network type (RS-422 4-wire or RS-485 2-wire) and verify compatibility with your DeviceNet master. Ensure you have a 1734-TB terminal block and shielded cables. For complete technical specifications, contact BluePLC Industrial. As a trusted supplier, BluePLC Industrial offers genuine Allen-Bradley modules with fast shipping. Verify current lifecycle status and availability with BluePLC Industrial before ordering to ensure seamless integration into your automation project.
| Model | 1734-485ASC |
|---|---|
| Brand | Allen-Bradley |
| Stock Status | In Stock |
| Warranty | One Year |
The allen-bradley-1734-485asc-serial-interface-module-for-point-i-o-systems offers processing performance suitable for its target application class. The exact scan time depends on program size and complexity.
The allen-bradley-1734-485asc-serial-interface-module-for-point-i-o-systems includes onboard memory as specified in the technical specifications. Memory is available for program storage, data tables, and configuration.
The allen-bradley-1734-485asc-serial-interface-module-for-point-i-o-systems is programmed using the manufacturer standard programming software. The software supports IEC 61131-3 programming languages.
The allen-bradley-1734-485asc-serial-interface-module-for-point-i-o-systems includes built-in communication ports as detailed in the specifications. Typical ports include serial (RS-232/485), USB, and Ethernet.
The allen-bradley-1734-485asc-serial-interface-module-for-point-i-o-systems is typically in stock and ships within 3-5 business days.
Interested in this product? Fill out the form below and we'll get back to you within 24 hours.
Explore the GE Fanuc IC693PWR321 Series 90-30 power supply: technical specs, output capacities, RS-485 communication,…
Read MoreExplore the GE Fanuc IC693PCM301 Programmable Coprocessor Module for Series 90-30 PLCs. Learn about its…
Read MoreExplore the GE IC694ALG392 RX3i analog output module: 8 channels, 0-10V/-10-10V, 0-20mA/4-20mA, 8ms update, 15/16-bit…
Read MoreExplore the GE Fanuc IC693PWR330 high-capacity power supply for Series 90-30 PLCs. Learn about its…
Read MoreExplore the GE IC695CPE310 PACSystems RX3i mid-range controller. This technical analysis covers processor speed, memory,…
Read MoreExplore the GE IC695ETM001 Ethernet interface module for PACSystems RX3i. This buyer's guide covers specs,…
Read MoreExplore the GE IC695NIU001 Ethernet Network Interface Unit for PACSystems RX3i. Learn about its dual…
Read MoreExplore the GE IC695PBS301 PROFIBUS slave module for RX3i PacSystems. Learn specs, applications, and integration…
Read More